Maximizing the time resolution of a particle counter with dead time
F. Gesualdi* and
A.D. Supanitsky*: corresponding author
Pre-published on:
July 25, 2023
Published on:
September 27, 2024
Abstract
We present a method for estimating the number of counts as a function of time of a counter with sub-units for which the expected count densities are the same. This is typically given in arrays of photo-multipliers in neutrino experiments, as well as in the segments of one segmented counter for indirect detection of cosmic rays. We take the latter as study case, and simulate and compare the performance of our algorithm in a detector like the Underground Muon Detector of the Pierre Auger Observatory. By properly accounting for the dead time of the counter, we provide estimates of the counts as a function of time to a single time-bin resolution.
DOI: https://doi.org/10.22323/1.444.0359
How to cite
Metadata are provided both in
article format (very
similar to INSPIRE)
as this helps creating very compact bibliographies which
can be beneficial to authors and readers, and in
proceeding format which
is more detailed and complete.