Functional Tests of 2S Modules for the CMS Phase-2 Tracker Upgrade with a MicroTCA-Based Readout System
L. Feld,
W. Karpinski,
K. Klein,
M. Lipinski,
M. Preuten* and
M. Rauch*: corresponding author
Pre-published on:
March 05, 2018
Published on:
March 20, 2018
Abstract
First full size 2S module prototypes for the CMS Phase-2 Outer Tracker Upgrade have been assembled. With two sensors of realistic dimensions and 16 CBC2 readout ASICs on two front-end hybrids, the characteristics of these novel and complex objects can be studied.
A MicroTCA based readout system was developed to test multiple front-end hybrids simultaneously. Therefore the concurrent information of the full module can be used for noise and signal studies.
DOI: https://doi.org/10.22323/1.313.0069
How to cite
Metadata are provided both in
article format (very
similar to INSPIRE)
as this helps creating very compact bibliographies which
can be beneficial to authors and readers, and in
proceeding format which
is more detailed and complete.