PSD performance and charge reconstruction with DAMPE
Y. Zhang*, Y. Zhang, T. Dong, P. Ma, Y. Yu, P. Bernardini on behalf of the DAMPE Collaboration
Pre-published on:
August 16, 2017
Published on:
August 03, 2018
Abstract
The DArk Matter Particle Explorer (DAMPE) is a satellite-borne device for detecting high energy electrons, gamma-rays, protons and heavy-ions in space. The Plastic Scintillator Detector (PSD) is the top-most of the four sub-detectors of DAMPE, which was designed to measure the charge of incident high-energy particles. It also serves as a veto detector for discriminating gamma-rays from charged particles. In this paper, we first introduce the structure and on-orbit operation status of the PSD. The calibration procedures, including the calibration of the pedestal, the dynode ratio, the detector alignment and the energy reconstruction, are then presented. Based on on-orbit data, the preliminary charge spectrum is obtained.
DOI: https://doi.org/10.22323/1.301.0168
How to cite
Metadata are provided both in "article" format (very similar to INSPIRE) as this helps creating
very compact bibliographies which can be beneficial to authors and
readers, and in "proceeding" format
which is more detailed and complete.